Welcome to the First Alert SC9120B User Manual! This comprehensive guide provides essential information for installing, testing, and maintaining your smoke and carbon monoxide alarm. Designed to ensure your safety, this manual covers key features, troubleshooting, and maintenance tips to help you get the most out of your device. By following the instructions, you can ensure optimal performance and protect your home and family effectively.
1.1 Overview of the SC9120B Smoke and Carbon Monoxide Alarm
The First Alert SC9120B is a hardwired smoke and carbon monoxide alarm with a 9-volt battery backup, ensuring continuous protection during power outages. It features a test/silence button, latching alarm indicators, and interconnectivity with other compatible BRK and First Alert detectors. Designed for homes with fossil fuel-burning appliances, this combo alarm provides dual protection against smoke and CO threats, offering reliable safety and peace of mind for your family.

1.2 Importance of Reading the Manual
Reading the First Alert SC9120B manual is crucial for proper installation, operation, and maintenance. It provides detailed instructions to ensure your alarm functions correctly, offering tips to avoid false alarms and extend its lifespan. Understanding the manual helps you utilize features like silencing, testing, and interconnectivity, ensuring maximum safety. Regular maintenance, outlined in the guide, is essential for reliable performance and compliance with safety standards, protecting your home and family effectively.

Key Features of the First Alert SC9120B
The SC9120B is a hardwired smoke and CO detector with battery backup, featuring a silence button, latching alarm, and interconnectivity with other compatible alarms for enhanced safety.
2.1 Hardwired Smoke and CO Detector with Battery Backup
The First Alert SC9120B is a hardwired smoke and carbon monoxide detector that includes a 9-volt battery backup, ensuring continuous operation during power outages. This dual-functionality ensures your home remains protected from both smoke and CO threats, even when the main power supply is interrupted. The battery backup provides reliable performance, giving you peace of mind and constant safety coverage.
2.2 Silence and Latching Features
The First Alert SC9120B features a test/silence button, allowing you to temporarily quiet false alarms or low-battery warnings. The latching alarm indicator ensures the red LED stays on after an alarm event, helping identify which detector triggered the alert. This feature remains active even after conditions return to normal, providing clear feedback for troubleshooting and ensuring safety. These functions enhance user control and simplify alarm management.
2.3 Interconnectivity with Other Alarms

The First Alert SC9120B supports interconnectivity with up to 18 compatible BRK and First Alert hardwired smoke and CO alarms. This feature ensures all interconnected alarms sound simultaneously when one detects smoke or CO, providing whole-home protection. The easy-adapter plugs eliminate the need for rewiring, making installation seamless. This interconnected system enhances safety by ensuring early warning throughout your home, even if danger is detected in just one area.

Installation Guidelines
Install the SC9120B in recommended areas, avoiding dead air spaces. Follow manual instructions for hardwired setup with battery backup. Ensure correct placement for optimal performance and safety.
3.1 Where to Install the Alarm
Install the First Alert SC9120B in areas where fire or CO risks are highest, such as bedrooms, hallways, and near fossil fuel-burning appliances. Avoid dead air spaces, kitchens, and bathrooms to minimize false alarms. Ensure the alarm is at least 10 feet away from cooking appliances and not near windows or doors to maintain reliability. Proper placement ensures optimal detection and safety for your home and family.
3.2 Step-by-Step Installation Process
Begin by mounting the bracket on a wall or ceiling, ensuring it is level and secure. Connect the wires to the alarm, following the manufacturer’s wiring diagram. Install the alarm onto the bracket and plug in the connector. Insert a fresh 9-volt battery for backup power. Test the alarm using the test/silence button to ensure proper function. Finally, secure the alarm to prevent tampering and verify all connections are tight for reliable operation.
3.3 Troubleshooting Common Installation Issues
Common installation issues include alarms not functioning after installation. Check all wire connections to ensure they are secure and correctly matched. Verify that the alarm is properly mounted and the battery is installed. If the alarm chirps, it may indicate a low battery or wiring issue. Refer to the LED indicators for error codes, such as a green light flashing for low battery. Test the alarm after installation to confirm proper operation and address any issues promptly.

Testing and Maintenance
Regular testing and maintenance ensure your SC9120B operates effectively. Test the alarm weekly, clean dust from sensors, and replace the battery annually. Check for error signals and address issues promptly to maintain reliability and safety.
4.1 Weekly Testing of the Alarm
Weekly testing ensures the SC9120B functions properly. Press the Test/Silence button to activate the horn, which emits 3 beeps. The Power/Smoke LED flashes green, confirming AC power, while the CO LED remains off. This verifies both smoke and CO detection capabilities. If the alarm is silenced during testing, it will resume normal operation afterward. Regular testing helps identify issues early, ensuring your safety and the device’s reliability.
4.2 Regular Maintenance Tips
Regular maintenance ensures optimal performance of your SC9120B alarm. Clean the unit monthly with a vacuum or soft brush to remove dust. Check the LEDs regularly to confirm proper operation. Replace the 9-volt battery annually or when the low-battery chirp sounds. Inspect wiring for damage and ensure connections are secure. Test the alarm weekly and replace it every 10 years, as CO sensors degrade over time. Proper upkeep ensures reliable protection for your home and family.
4.3 How to Silence the Alarm
To silence the First Alert SC9120B alarm, press and hold the test/silence button until the alarm stops. This feature is useful during false alarms or when cooking smoke triggers the detector. Note that silencing does not reset the alarm; it only temporarily stops the noise. The alarm will automatically reset once the air clears or the underlying issue is resolved.

Understanding the LEDs and Indicators
The First Alert SC9120B uses LEDs to indicate its status. A steady green light shows normal operation, while red flashes signal smoke or CO detection. A yellow blink indicates low battery or malfunction, and a red pulse signals CO detection. These indicators help you quickly identify the alarm’s status and any potential issues.
5.1 Normal Operations and LED Behavior
During normal operation, the First Alert SC9120B displays a steady green LED, indicating AC power and proper function. The CO LED remains off, and the horn is silent. When testing, the horn emits 3 beeps, and the Power/Smoke LED flashes red in sync. For low battery, the green LED flashes once a minute, and the horn chirps. Malfunction signals include 3 green flashes and 3 horn chirps. These indicators ensure clear communication of the alarm’s status and any issues.
5.2 LED Indicators for Smoke and CO Detection
The First Alert SC9120B uses LED indicators to signal smoke and CO detection. When smoke is detected, the horn emits 3 beeps, and the Power/Smoke LED flashes red in sync. For CO detection, the horn sounds 4 beeps, and the CO LED flashes red. After the alarm, the LED continues to flash every 2 seconds. The CO LED also flashes red during and after CO detection, while the smoke LED remains off for CO events. These distinct patterns help identify the type of hazard present.
5.3 Low Battery and Malfunction Signals
The First Alert SC9120B signals low battery with a single chirp every minute and a flashing green LED. For malfunctions, the horn chirps three times, and the green LED flashes three times. If the alarm reaches its end of life, it chirps five times, and the green LED flashes five times. These signals ensure prompt attention to maintain your safety and the alarm’s reliability. Always address these indicators to keep your device functioning properly.
How the Alarm Works
The First Alert SC9120B detects smoke and CO, triggering alarms with specific patterns. It features latching indicators to identify the source of the alert, ensuring clear notifications and quick responses.
6.1 Smoke Detection and Alarm Patterns
The First Alert SC9120B detects smoke using ionization technology, triggering a loud alarm with three beeps, a pause, and three more beeps. The Power/Smoke LED flashes red in sync with the horn during an alarm. After the threat subsides, the LED continues to flash red every two seconds, engaging the latching feature to indicate the source of the alert. This clear pattern ensures quick identification and response to potential fires.
6.2 Carbon Monoxide Detection and Alarm Patterns
The First Alert SC9120B detects carbon monoxide and alerts with four beeps, a pause, and four more beeps. The CO LED flashes red in sync with the alarm. Once CO levels drop, the LED continues to flash red every two seconds, engaging the latching feature to identify the alarm source. This pattern ensures prompt response to potential CO threats, enhancing home safety.
6.3 Latching Features and Alarm Memory
The First Alert SC9120B features latching capabilities to identify the alarm source after conditions return to normal. The red LED on the initiating unit flashes every two seconds, while others show a steady green light. This memory function helps pinpoint which detector triggered the alarm, ensuring quick identification of potential hazards. The latching feature remains active until reset, providing clear feedback for troubleshooting and maintaining home safety effectively.

Troubleshooting Common Issues
This section helps resolve common issues like false alarms, low battery signals, and malfunction indicators. Troubleshooting steps include checking for obstructions, replacing batteries, and resetting the alarm.
7.1 Common Problems and Solutions
Common issues with the First Alert SC9120B include false alarms, low battery signals, and malfunction indicators. False alarms may occur due to humidity or dust. Solutions include cleaning the sensor, ensuring proper installation, and avoiding placement in areas with high moisture. For low battery signals, replace the 9-volt battery promptly. Malfunction signals, indicated by three chirps, suggest a system error; reset the alarm by silencing it and ensuring proper power connection. Regular testing and maintenance can prevent these issues.
7.2 Resolving False Alarms
False alarms on the First Alert SC9120B can often be resolved by cleaning the sensor with a vacuum or soft brush to remove dust. Ensure the alarm is not installed in areas prone to humidity, such as near bathrooms or kitchens. If the alarm sounds without cause, press the Test/Silence button to silence it. Regular maintenance and proper installation can help minimize false alarms. Always follow the manual’s guidelines for optimal performance.
7.3 Addressing End-of-Life Signals
The First Alert SC9120B signals its end-of-life with 5 chirps every minute and 5 green LED flashes. Replace the entire unit immediately, as the sensor degrades over time. Pressing the Test/Silence button will not reset the alarm. Ensure a new alarm is installed to maintain safety. Always follow the manual’s replacement guidelines for proper functionality and continued protection.

Safety Tips and Best Practices
Ensure your home is equipped with working smoke and CO alarms. Replace batteries annually, test weekly, and install alarms in every sleeping area and level of your home.
8.1 Fire Safety and Emergency Procedures
Ensure a fire escape plan is in place and practice it regularly with all household members. Test your SC9120B weekly and never ignore alarms. If the alarm sounds, evacuate immediately, stay low to avoid smoke, and never use elevators. Designate a safe meeting spot outside the home. Call 911 once safely outside. Stay calm, follow the plan, and prioritize safety above all. Regular drills ensure preparedness in emergencies.
8.2 CO Poisoning Prevention and Response
Prevent CO poisoning by ensuring proper ventilation in areas with fuel-burning appliances. Never use generators indoors. If the SC9120B detects CO, evacuate immediately, open windows, and call emergency services. Familiarize yourself with alarm patterns: four beeps for CO. Regularly test the alarm and replace the battery annually. Replace the unit every 10 years as CO sensors degrade over time. Stay informed and prepared to act swiftly in emergencies.

8.3 Regular Replacement of Alarms
Replace your First Alert SC9120B every 10 years or when the end-of-life signal sounds (five chirps every minute). This ensures optimal performance and safety. The CO sensor degrades over time, and replacing the unit maintains reliable protection. Plan ahead to upgrade all alarms in your home simultaneously for consistent safety. Always follow the manufacturer’s guidelines for replacement to ensure your home remains protected from smoke and carbon monoxide threats.
Compliance and Regulatory Information
The First Alert SC9120B meets UL 217 and UL 2034 standards for smoke and CO alarms, ensuring compliance with safety regulations. It adheres to NFPA 72 requirements.
9.1 Agency Recommendations for Smoke and CO Alarms
Agencies like UL and NFPA recommend installing smoke and CO alarms on every level of the home and outside sleeping areas. The First Alert SC9120B meets UL 217 and UL 2034 standards, ensuring reliable detection and compliance with safety regulations. It adheres to NFPA 72 guidelines, providing optimal protection for your family. Proper installation and maintenance, as outlined in the manual, are crucial for meeting these standards and ensuring effective performance.
9.2 Special Compliance Considerations
The First Alert SC9120B complies with UL 217 and UL 2034 standards for smoke and CO alarms. It meets NFPA 72 guidelines, ensuring reliable performance. Special considerations include avoiding installation in dead air spaces and ensuring proper placement as outlined in the manual. Additionally, the alarm must be interconnected with compatible units for whole-home protection. Always consult local regulations for specific requirements, as they may vary. Proper installation and maintenance are essential for compliance and safety.
9.3 General Limitations of Smoke/CO Alarms
No smoke or carbon monoxide alarm can detect all fire or CO conditions. The SC9120B may not respond to smoldering fires or CO levels that rise slowly. False alarms can occur due to steam, humidity, or cooking fumes. The CO sensor has a limited lifespan (5-7 years) and must be replaced. Alarms may not detect gases other than CO or smoke. Always supplement with additional safety measures for comprehensive protection.
Conclusion
The First Alert SC9120B user manual provides essential guidance for safe and effective use. Regular maintenance and proper installation ensure optimal performance, protecting your home and family.
10.1 Summary of Key Points
The First Alert SC9120B user manual emphasizes proper installation, regular testing, and maintenance for optimal performance. Key features include hardwired functionality with battery backup, latching indicators, and interconnectivity. The alarm detects both smoke and CO, with distinct LED signals for each hazard. Regular testing ensures reliability, while maintenance tips like cleaning and battery replacement prolong its lifespan. Compliance with safety standards and understanding LED indicators are crucial for effective use and home safety.
10.2 Final Tips for Safe and Effective Use
Always follow the manual’s guidelines for installation, testing, and maintenance to ensure your First Alert SC9120B operates effectively. Replace the alarm every 10 years, as CO sensors degrade over time. Understand LED indicators to identify alarms, low batteries, or malfunctions. Test the alarm weekly and clean it regularly to avoid false alarms. Keep the user manual handy for quick reference and ensure all household members understand its operation for maximum safety and protection.