Validation of walkway tribometers pdf Killarney

validation of walkway tribometers pdf

Validation of Walkway Slip Resistance Measurements A Gait Repeatability and bias of two walkway safety tribometers. Journal of Testing and Evaluation, 27(6), pp. 368-374. Brault JB, Wheeler JB, Siegmund GP , Brault …

Comments on ASTM F2508 – 13 omicsonline.org

ASTM F2508 13 - Standard Practice for Validation. Repeatability and Bias of Two Walkway Safety Tribometers, Powers CM, Kulig K, Flynn JE, Brault JR. "Journal of Testing and Evaluation," November 1999. "Journal of …, This practice is intended to establish the procedures for validation, calibration, and certification of walkway tribometers. This practice provides a walkway tribometer supplier with a procedure and suite of reference surfaces to validate his walkway tribometer by ….

1.1 This practice is intended to establish the procedures for validation, calibration, and certification of walkway tribometers. 1.2 This practice provides a walkway tribometer supplier with a procedure and suite of reference surfaces to validate his walkway tribometer by properly ranking and tribometers (and as a function of the test foot preparation). Chang et al have determined a one in a million Chang et al have determined a one in a million risk of slipping for a UCoF of 0.30 at normal walking speed, and a UCoF of 0.33 at fast walking speed, where

Validation of the kinect for gait analysis using the GAITRite wal kway Greet Baldewijns 1 ,2 ,3, Geert Verheyden 4, Bart Vanrumste 1 ,2 ,3 and Tom Croonenborghs 1 ,5 Validation and calibration of a walkway tribometer as defined by this practice does not imply validation and calibration under all combinations of test foot materials and walkway surfaces. 5.3.4 The validation and calibration procedure defined by this practice is not intended to establish a “safe threshold” value for any walkway surface.

Powers CM et al. Validation of walkway tribometers: establishing a reference standard. Journal of Forensic Sciences , March 2010, Volume 55, Number 2, 366-370. Leffler JP. Repeatability and bias of two walkway safety tribometers. Journal of Testing and Evaluation, 27(6), pp. 368-374. Brault JB, Wheeler JB, Siegmund GP , Brault …

TAFE NSW constructed a walkway to guarantee the safety of participants. The use of a trade show to conduct the testing in a public forum prevented the psychophysical testing from being as rigorous as is possible in a laboratory environment (Marchal and Jacques, 2013). Validation of Walkway Tribometers: Establishing a Reference Standard * The purpose of this study was to define a tribometer reference standard and use it to assess the performance of various tribometers.

Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect's 3D body point's time series. •ASTM F2508, "Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces". The F2508 Standard Practice establishes a methodology to assure the precision and repeatability of walkway tribometers. n INTERNAL USE ONLY

Author Information. 1. Musculoskeletal Biomechanics Research Laboratory, Division of Biokinesiology & Physical Therapy, University of Southern California, 1540 E ASTM F2508 “Standard Practice for Validation, Calibration, and Certification of Walkway Tribometers Using Reference Surfaces” Division 9 Flooring - Slip Resistance Slip Resistant - the provision of adequate slip resistance to reduce the likelihood of slip for pedestrians using reasonable care on the walkway surface under expected use conditions. Slip Resistance - the relative force that

Validation of Walkway Tribometers: Establishing a Reference Standard * The purpose of this study was to define a tribometer reference standard and use it to assess the performance of various tribometers. 1.1 This practice is intended to establish the procedures for validation, calibration, and certification of walkway tribometers. 1.2 This practice provides a walkway tribometer supplier with a procedure and suite of reference surfaces to validate his walkway tribometer by properly ranking and

Tribometers (Slip Test Meters) Compared. This page contains information about the world’s most used tribometers, or slip test meters. The information on this page is available on a convenient, printable, one-page pdf file called Tribometers Compared if you’d like to print it out. ASTM F2508 “Standard Practice for Validation, Calibration, and Certification of Walkway Tribometers Using Reference Surfaces” Texture Designation Finish texture (Average Maximum Peak Heights) (mils) Finish texture (Average Maximum Peak Heights) (microns) CFT-A 2 - 6 mils 50 - 165 microns CFT-B 7 – 18 mils 166 - 465 microns CFT-C 19 – 30 mils 466 - 775 microns CFT-D 31 - 50 mils 776

Validation of the spatial parameters was done by marking directly on the walkway, the method of paper-pencil on a sheet of paper and the method of inking the paws. For the validation of the temporal parameters, a watch chronometer was used. The introduction of ASTM International Standard F2508 Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, has produced a method which allows validation of each type of tribometer and the values generated during testing.

About the presenter Christopher M. Powers Christopher M. Powers is an Associate Professor in the Division of Biokinesiology & Physical Therapy, and Co-Director of the MBRL at Tribometers are mechanical devices used to measure walkway coefficient of friction (COF) for the purpose of assessing slip risk. The purpose of this study was to define a tribometer reference

New Standards Change the Landscape of Walkway Safety

validation of walkway tribometers pdf

Validation of the Kinect for Gait Analysis Using the. Russell Fote & Associates, Inc. Brookfield, WI Phone: (262) 781-4496 Chicago, IL Phone: (773) 380-0830 Slip Resistance and Validation of the English XL (continued from page two) Page 3, o ASTM F2508 “Standard for Validation, Calibration & Certification of Walkway Tribometers” o ANSI A-A-55617 & A-A-55619 “Medium & Heavy Duty Industrial Caster Standard” o ANSI/RESNA Wheelchair Standards Vol. 1 & 2.

XL VIT with Sequencer F2508 Validation Excel Tribometers. new standard of F2508-13: “standard practice for validation, calibration and certificate of walkway Tribometers Using Reference Surfaces” adapted by American Society of Testing and Materials, The introduction of ASTM International Standard F2508 Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, has produced a method which allows.

ASTM F2508-16e1 Techstreet

validation of walkway tribometers pdf

ASTM F2508 12 Standard Practice for Validation. Russell Fote & Associates, Inc. Brookfield, WI Phone: (262) 781-4496 Chicago, IL Phone: (773) 380-0830 Slip Resistance and Validation of the English XL (continued from page two) Page 3 development of the Instrumented Walkway and presents an experimental preliminary validation of its capability to estimate the impedance of a system with time-varying dynamics..

validation of walkway tribometers pdf

  • Comments on ASTM F2508 – 13 omicsonline.org
  • BIOMECHANICS INJURY AND DESIGN CONSIDERATIONS
  • ASTM F250811 standard.no

  • Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces Item type: Standard tribometers give varied COF values for the same surface. In the current study, only two of the nine tribometers tested (the In the current study, only two of the nine tribometers tested (the Tortus II and Mark III) met our compliance criteria by both correctly ranking all 6 conditions and differentiating between

    tribometers (and as a function of the test foot preparation). Chang et al have determined a one in a million Chang et al have determined a one in a million risk of slipping for a UCoF of 0.30 at normal walking speed, and a UCoF of 0.33 at fast walking speed, where standard practice for validation, calibration, and certification of walkway tribometers using reference surfaces - includes standard + redline (pdf)

    The introduction of ASTM International Standard F2508 Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, has produced a method which allows ASTM F2508 Standard Practice for Validation, Calibration, and Certification of Walkway Tribometers Using Reference Surfaces. It is important to point out that the standard does not specifically reference Fluid-Applied Coatings and Fluid-Applied Flooring surfaces. The absence of the fluid-applied flooring means that the standard must be stated as “modified” to pertinent to fluidapplied

    of Walkway Tribometers Using Reference Surfaces”. The purpose of the standard is to provide a procedure for The purpose of the standard is to provide a procedure for validation and calibration of tribmeters so that that their readings of the Coefficient Of Friction (COF) in wet conditions Powers CM et al. Validation of walkway tribometers: establishing a reference standard. Journal of Forensic Sciences , March 2010, Volume 55, Number 2, 366-370. Leffler JP.

    The introduction of ASTM International Standard F2508 Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, has produced a method which allows validation of each type of tribometer and the values generated during testing. of Walkway Tribometers Using Reference Surfaces”. The purpose of the standard is to provide a procedure for The purpose of the standard is to provide a procedure for validation and calibration of tribmeters so that that their readings of the Coefficient Of Friction (COF) in wet conditions

    This article highlights the role of biomechanics as a design consideration surrounding a variety of activities and exposures, as well as in less frequent traumatic events. evaluation, and validation. Using this critical thinking approach, rather than relying on a device’s Using this critical thinking approach, rather than relying on a device’s measurements, should help the risk control consultant evaluate walkway surfaces.

    ASTM F2508 (2013), Standard Practice for Validation, Calibration and Certification of Walkway Tribometers Using Reference Surfaces, is based on human ambulation studies conducted with a set of carefully selected materials at the University of Southern California (USC) Musculoskeletal Biomechanics Laboratory (Powers et al., 2010). Validation of Walkway Slip Resistance Measurements: A Gait Based Approach Christopher M. Powers, Ph.D.1, Mark G. Blanchette, M Tribometers are devices that measure the slip resistance of walkway surfaces. There are over thirty tribometers that are commercially available, and each varies in its mechanical design and friction calculation method (Chang, Gronqvist et al. 2001). As a result

    ASTM F2508 (2011) Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, the American Society for Standards and Materials, West Conshohocken, PA, USA. 3. Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect's 3D body point's time series.

    Practice for Validation and Calibration of Walkway Tribometers Using R... ANSI/NFSI B101.0-2012 Walkway Surface Auditing Procedure for the Measurement of Walkway Slip... Recently, the authors designed and fabricated an Instrumented Walkway for the estimation of the ankle mechanical impedance in the sagittal and frontal planes during walking in arbitrary directions [1].

    Practice for Validation and Calibration of Walkway Tribometers Using R... ANSI/NFSI B101.0-2012 Walkway Surface Auditing Procedure for the Measurement of Walkway Slip... Recently, the authors designed and fabricated an Instrumented Walkway for the estimation of the ankle mechanical impedance in the sagittal and frontal planes during walking in arbitrary directions [1].

    About the presenter Christopher M. Powers Christopher M. Powers is an Associate Professor in the Division of Biokinesiology & Physical Therapy, and Co-Director of the MBRL at 1.1 This practice is intended to establish the procedures for validation, calibration, and certification of walkway tribometers. 1.2 This practice provides a walkway tribometer supplier with a procedure and suite of reference surfaces to validate his walkway tribometer by properly ranking and differentiating the …

    NIOSH Personal Protective Equipment Information (PPE-Info)

    validation of walkway tribometers pdf

    Standard Practice for Validation Calibration and. F-2508-2011 "Standard Practice for Validation and Calibration of Walkway Tribometers using Reference Surfaces” ASTM F-06 Resilient Flooring No Slip resistance standards. ANSI/ASSE A1264.2-2013 Applies only to workplaces and not the general public Suggests that floors meet a minimum dry SCOF of 0.5 Addresses 4-areas Floor Surface Characteristics Footwear Traction Properties …, F2508 Practice for Validation, Calibration, and Certification of Walkway Tribometers Using Reference Surfaces F2892 Specification for Performance Requirements for Soft Toe Protective Footwear (Non-Safety / Non-Protective.

    ASTM F2508 Standard Practice for Validation Calibration

    The Changing World of Slip-and-Fall Analysis assp.org. ASTM F2508 “Standard Practice for Validation, Calibration, and Certification of Walkway Tribometers Using Reference Surfaces” Division 9 Flooring - Slip Resistance Slip Resistant - the provision of adequate slip resistance to reduce the likelihood of slip for pedestrians using reasonable care on the walkway surface under expected use conditions. Slip Resistance - the relative force that, Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces Item type: Standard.

    new standard of F2508-13: “standard practice for validation, calibration and certificate of walkway Tribometers Using Reference Surfaces” adapted by American Society of Testing and Materials Validation of Walkway Tribometers: Establishing a Reference Standard * The purpose of this study was to define a tribometer reference standard and use it to assess the performance of various tribometers.

    Recently, the authors designed and fabricated an Instrumented Walkway for the estimation of the ankle mechanical impedance in the sagittal and frontal planes during walking in arbitrary directions [1]. Author Information. 1. Musculoskeletal Biomechanics Research Laboratory, Division of Biokinesiology & Physical Therapy, University of Southern California, 1540 E

    Repeatability and Bias of Two Walkway Safety Tribometers, Powers CM, Kulig K, Flynn JE, Brault JR. "Journal of Testing and Evaluation," November 1999. "Journal of … evaluation, and validation. Using this critical thinking approach, rather than relying on a device’s Using this critical thinking approach, rather than relying on a device’s measurements, should help the risk control consultant evaluate walkway surfaces.

    The introduction of ASTM International Standard F2508 Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, has produced a method which allows validation of each type of tribometer and the values generated during testing. The introduction of ASTM International Standard F2508 Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, has produced a method which allows

    Excel Tribometers LLC certifies and affirms that the XL VIT with sequencer-model conforms to all requirements of ASTM F2508-11 Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, which conformance ABC4: La Trobe University, Melbourne, November 28-30, 2002 94 VALIDATION OF THE GAITRITE WALKWAY SYSTEM USING 2 -DIMENSIONAL MOTION ANALYSIS …

    ASTM F2508 (2011) Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, the American Society for Standards and Materials, West Conshohocken, PA, USA. 3. development of the Instrumented Walkway and presents an experimental preliminary validation of its capability to estimate the impedance of a system with time-varying dynamics.

    ASTM F2508 (2013), Standard Practice for Validation, Calibration and Certification of Walkway Tribometers Using Reference Surfaces, is based on human ambulation studies conducted with a set of carefully selected materials at the University of Southern California (USC) Musculoskeletal Biomechanics Laboratory (Powers et al., 2010). scope: This practice is intended to establish the procedures for validation, calibration, and certification of walkway tribometers. This practice provides a walkway tribometer supplier with a procedure and suite of reference surfaces to validate his walkway tribometer by properly ranking and differentiating the …

    tribometer that meets ASTM F2508 Standard Practice for Validation, Certification of Walkway Tribometers Using Reference Surfaces. However, this still does not establish a methodology for verifying a slip resistance of 0.5, as ASTM F2508 is not a traction testing methodology in itself. ASTM F2508 will be discussed later in this paper. • ASTM F1637 Standard Practice for Safe Walking Repeatability and Bias of Two Walkway Safety Tribometers, Powers CM, Kulig K, Flynn JE, Brault JR. "Journal of Testing and Evaluation," November 1999. "Journal of …

    1.1 This practice is intended to establish the procedures for validation, calibration, and certification of walkway tribometers. 1.2 This practice provides a walkway tribometer supplier with a procedure and suite of reference surfaces to validate his walkway tribometer by properly ranking and F-2508-2011 "Standard Practice for Validation and Calibration of Walkway Tribometers using Reference Surfaces” ASTM F-06 Resilient Flooring No Slip resistance standards. ANSI/ASSE A1264.2-2013 Applies only to workplaces and not the general public Suggests that floors meet a minimum dry SCOF of 0.5 Addresses 4-areas Floor Surface Characteristics Footwear Traction Properties …

    Repeatability and Bias of Two Walkway Safety Tribometers, Powers CM, Kulig K, Flynn JE, Brault JR. "Journal of Testing and Evaluation," November 1999. "Journal of … It meets the requirements of ASTM F2508 for the validation and certification of walkway tribometers, as tested by an independent laboratory. Part # 9013038 BOT-3000E Kit - $6,995.00

    The science behind codes and standards for safe walkways. Russell Fote & Associates, Inc. Brookfield, WI Phone: (262) 781-4496 Chicago, IL Phone: (773) 380-0830 Slip Resistance and Validation of the English XL (continued from page two) Page 3, Floor slip resistance is routinely evaluated using walkway tribometers. These devices use samples of the floor surface and outsole materials to measure utilized friction, either in a laboratory setting or in situ ..

    Validation of the Kinect for Gait Analysis Using the

    validation of walkway tribometers pdf

    J2 Engineering Inc.. Repeatability and Bias of Two Walkway Safety Tribometers, Powers CM, Kulig K, Flynn JE, Brault JR. "Journal of Testing and Evaluation," November 1999. "Journal of …, tribometers (and as a function of the test foot preparation). Chang et al have determined a one in a million Chang et al have determined a one in a million risk of slipping for a UCoF of 0.30 at normal walking speed, and a UCoF of 0.33 at fast walking speed, where.

    The effect of subject awareness and prior slip experience. Validation of Walkway Tribometers: Establishing a Reference Standard* ABSTRACT: Tribometers are mechanical devices used to measure walkway coefficient of friction (COF) for the purpose of assessing slip risk. The purpose of this study was to define a tribometer reference standard and use it to assess the performance of various tribometers. Eighty subjects were randomly assigned to walk across, Comments on ASTM F2508 – 13 Oren Masory Department of Ocean and Mechanical Engineering Florida Atlantic University Boca Raton, FL 33431 masoryo@fau.edu ABSTRACT In 2013 the American Society of Testing and Materials (ASTM) F13 committee on Pedestrian/Walkway Safety and Footwear, adapted a new standard F2508-13 “Standard Practice for Validation, Calibration, and Certification of Walkway.

    Validation of Walkway Tribometers Establishing a

    validation of walkway tribometers pdf

    XL VIT Base-Model F2508 Std Foot Validation Report. of Walkway Tribometers Using Reference Surfaces”. The purpose of the standard is to provide a procedure for The purpose of the standard is to provide a procedure for validation and calibration of tribmeters so that that their readings of the Coefficient Of Friction (COF) in wet conditions Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect's 3D body point's time series..

    validation of walkway tribometers pdf

  • Comments on ASTM F2508 13 Florida Atlantic University
  • Standard Practice for Validation Calibration and

  • The introduction of ASTM International Standard F2508 Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, has produced a method which allows tribometer that meets ASTM F2508 Standard Practice for Validation, Certification of Walkway Tribometers Using Reference Surfaces. However, this still does not establish a methodology for verifying a slip resistance of 0.5, as ASTM F2508 is not a traction testing methodology in itself. ASTM F2508 will be discussed later in this paper. • ASTM F1637 Standard Practice for Safe Walking

    Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces Item type: Standard Tribometers (Slip Test Meters) Compared. This page contains information about the world’s most used tribometers, or slip test meters. The information on this page is available on a convenient, printable, one-page pdf file called Tribometers Compared if you’d like to print it out.

    1.1 This practice is intended to establish the procedures for validation, calibration, and certification of walkway tribometers. 1.2 This practice provides a walkway tribometer supplier with a procedure and suite of reference surfaces to validate his walkway tribometer by properly ranking and Comments on ASTM F2508 – 13 Oren Masory Department of Ocean and Mechanical Engineering Florida Atlantic University Boca Raton, FL 33431 masoryo@fau.edu ABSTRACT In 2013 the American Society of Testing and Materials (ASTM) F13 committee on Pedestrian/Walkway Safety and Footwear, adapted a new standard F2508-13 “Standard Practice for Validation, Calibration, and Certification of Walkway

    1.1 This practice is intended to establish the procedures for validation, calibration, and certification of walkway tribometers. 1.2 This practice provides a walkway tribometer supplier with a procedure and suite of reference surfaces to validate his walkway tribometer by properly ranking and differentiating the … Validation of Walkway Tribometers: Establishing a Reference Standard* ABSTRACT: Tribometers are mechanical devices used to measure walkway coefficient of friction (COF) for the purpose of assessing slip risk. The purpose of this study was to define a tribometer reference standard and use it to assess the performance of various tribometers. Eighty subjects were randomly assigned to walk across

    The introduction of ASTM International Standard F2508 Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, has produced a method which allows Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect's 3D body point's time series.

    1.1 This practice is intended to establish the procedures for validation, calibration, and certification of walkway tribometers. 1.2 This practice provides a walkway tribometer supplier with a procedure and suite of reference surfaces to validate his walkway tribometer by properly ranking and Fall accidents generate large injury, morbidity, and mortality costs. Many falls are caused by pedestrian slips, which are in turn a result of one or a combination of factors: pedestrian, walkway

    Excel Tribometers LLC certifies and affirms that the XL VIT with sequencer-model conforms to all requirements of ASTM F2508-11 Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, which conformance ABSTRACT: The purpose of this study was to assess the viability of using slip risk (as quantified during human subject walking trials) to create a reference standard against which tribometer readings could be compared. First, human subjects (N=84)

    Validation of the spatial parameters was done by marking directly on the walkway, the method of paper-pencil on a sheet of paper and the method of inking the paws. For the validation of the temporal parameters, a watch chronometer was used. Validation of Walkway Tribometers: Establishing a Reference Standard* ABSTRACT: Tribometers are mechanical devices used to measure walkway coefficient of friction (COF) for the purpose of assessing slip risk. The purpose of this study was to define a tribometer reference standard and use it to assess the performance of various tribometers. Eighty subjects were randomly assigned to walk across

    ABC4: La Trobe University, Melbourne, November 28-30, 2002 94 VALIDATION OF THE GAITRITE WALKWAY SYSTEM USING 2 -DIMENSIONAL MOTION ANALYSIS … Powers CM et al. Validation of walkway tribometers: establishing a reference standard. Journal of Forensic Sciences , March 2010, Volume 55, Number 2, 366-370. Leffler JP.

    Practice for Validation and Calibration of Walkway Tribometers Using R... ANSI/NFSI B101.0-2012 Walkway Surface Auditing Procedure for the Measurement of Walkway Slip... ASTM F2508 (2011) Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, the American Society for Standards and Materials, West Conshohocken, PA, USA. 3.

    validation of walkway tribometers pdf

    About the presenter Christopher M. Powers Christopher M. Powers is an Associate Professor in the Division of Biokinesiology & Physical Therapy, and Co-Director of the MBRL at ASTM F2508 (2011) Standard Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, the American Society for Standards and Materials, West Conshohocken, PA, USA. 3.